Wuxi green heat exchanger Co., Ltd

Wuxi Green Heat Exchanger Co.,Ltd

Manufacturer from China
Active Member
4 Years
Home / Products / Gasket Plate Heat Exchanger /

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Contact Now
Wuxi green heat exchanger Co., Ltd
City:wuxi
Country/Region:china
Contact Person:MrJin
Contact Now

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Ask Latest Price
Video Channel
Brand Name :GHE
Model Number :G32M
Certification :CE,9001
Place of Origin :JIangsu,China
MOQ :1 piece
Price :USD 1000-10000 /per piece
Payment Terms :L/C, T/T
Supply Ability :5000 pieces /year
Delivery Time :10 working days
Packaging Details :Wooden package
Frame Material :Carbon Steel,SS, etc
Plate Material :AISI 304,AISI316,Titanium,Nickel,etc
Gasket Rubber :NBR,EPDM,VITON,etc
Port Size :1 1/4
Customized Available :Yes
Applicable Industries :HVAC,Power Generation,Ferrous Metallurgy
Machinery Test Report :Provided
Structure :Plate Heat Exchanger
Maximum Working Pressure :15bar
Max Temp :180 degrees
Video outgoing-inspection :Provided
Warranty of core components :1 year
color :customized
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

gasketed heat exchanger model G32 pharmacy and health applications high efficient diversion areas

applications: pharmacy and health , such as emulsion cooling , suspension liquid cooling, plasma heating, citric acid heating , transfusion cooling , borate heating, antibiotic solution heating, starch fluid heating.

Technical Dimension Data For Gasket Plate Heat Exchanger
Model H[mm] W[mm] Min L[mm] Max L[mm] VC [mm] HC [mm] Max Temp [0C] Max Pressure [Barg] Flange Size MaxFlowRate [M3/H]
G32 M3 470 180 400 650 357 60 180 16 1 1/4 14
G60B/G60M M6/M6M 920 320 500 1500 640 140 180 16 DN50 43
GS65 TS6M 680 400 530 1430 380 202 180 16/20.8 DN65 72
G100B/G100M M10M/M15B 1045 454 700 2300 719 225 180 16 DN100 170
GL100B TL10B 1923 480 850 2350 1338 225 180 16 DN100 170
1180 440 850 2350 719 225 180 16 DN100 155
G150B/G150M M15M/M15B 1815 610 1150 2050 1294 298 180 16 DN150 380
GS200M TS200M 1420 760 900 2700 728 338 180 16 DN200 680
G200B/G200M M20M/M20B 2200 780 1250 3350 1478 353 180 16 DN200 810
G250B MX25B 2680 910 1550 3350 1939 440 180 16 DN250 1530
G300 M30 2882 1150 1650 5200 1842 596 180 16 DN300 1730

Standard Design

The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fix frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interpolate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program.

The plate corrugations promote fluid turbulence and support the plates against differential pressure. The frame plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates.

Working Principle

Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer.

The advanced frame structure

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Plate and gasket features

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Process flow combination

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Factory Production

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

​ ​

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Gasket Plate Heat Exchanger G32 Pharmacy Health Applications 15bar High Efficient Diversion Areas

Market Areas
Our gasket plate heat exchaners is widely sold to most foreign countries like Australia,Spain ,Mexico ,Russia.most Europe,south America and Southeast Asia countries . major applications are for chillers,water heating and cooling, oil cooler,chemical industry,food process, etc
Our Services
1.Before Service: All the process of Technical Production deportment and Strict Quality Control System. We also can provide the sample for your test quality.
2.Middle Service: Any questions, pls feel free to contact us.
3.After Service: All the products problems, pls call us and E- mail us at any time, we will reply to you at the shortest time.

Payment Terms

1.We accept TT and L/C
Packaging & Shipping
Standard export packing .
Shipping Terms:
1.For the sample order: we also use International Express freight: Such as: DHL, TNT, EMS, UPS and so on.
2.For large quantity order, we will consider the Air or Sea Transport, all the detail terms we will discuss in the Contract.
Inquiry Cart 0